{"id":"CVE-2024-52051","revision":null,"records":[{"revision":"b5577a13142540de9c243d5f044b49ed","observedAt":"2026-10-23T15:48:27.903+00:00","statement":{"source":"cve-program","id":"CVE-2024-52051","aliases":[],"title":"A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC S7-PLCSIM V18 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 6), SIMATIC STE…","description":"A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC S7-PLCSIM V18 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 6), SIMATIC STEP 7 Safety V19 (All versions < V19 Update 4), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC WinCC Unified PC Runtime V18 (All versions), SIMATIC WinCC Unified PC Runtime V19 (All versions < V19 Update 4), SIMATIC WinCC Unified V17 (All versions < V17 Update 9), SIMATIC WinCC Unified V18 (All versions < V18 Update 6), SIMATIC WinCC Unified V19 (All versions < V19 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1). The affected devices do not properly sanitize  user-controllable input when parsing user settings. This could allow an attacker to locally execute arbitrary commands in the host operating system with the privileges of the user.","state":0,"publishedAt":"2024-12-10T13:53:57.576+00:00","modifiedAt":"2026-10-13T09:18:15.738+00:00","affected":[{"ecosystem":"Vendor product","name":"SIMATIC S7-PLCSIM V17","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SIMATIC S7-PLCSIM V17\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"*\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"SIMATIC S7-PLCSIM V18","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SIMATIC S7-PLCSIM V18\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"*\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"SIMATIC STEP 7 Safety V17","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SIMATIC STEP 7 Safety V17\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"V17 Update 9\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"SIMATIC STEP 7 Safety V18","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SIMATIC STEP 7 Safety V18\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"V18 Update 6\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"SIMATIC STEP 7 Safety V19","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SIMATIC STEP 7 Safety V19\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"V19 Update 4\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"SIMATIC STEP 7 V17","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SIMATIC STEP 7 V17\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"V17 Update 9\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"SIMATIC STEP 7 V18","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SIMATIC STEP 7 V18\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"V18 Update 6\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"SIMATIC STEP 7 V19","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SIMATIC STEP 7 V19\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"V19 Update 4\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"SIMATIC WinCC Unified PC Runtime V18","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SIMATIC WinCC Unified PC Runtime V18\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"*\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"SIMATIC WinCC Unified PC Runtime V19","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SIMATIC WinCC Unified PC Runtime V19\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"V19 Update 4\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"SIMATIC WinCC Unified V17","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SIMATIC WinCC Unified V17\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"V17 Update 9\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"SIMATIC WinCC Unified V18","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SIMATIC WinCC Unified V18\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"V18 Update 6\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"SIMATIC WinCC Unified V19","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SIMATIC WinCC Unified V19\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"V19 Update 4\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"SIMATIC WinCC V17","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SIMATIC WinCC V17\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"V17 Update 9\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"SIMATIC WinCC V18","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SIMATIC WinCC V18\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"V18 Update 6\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"SIMATIC WinCC V19","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SIMATIC WinCC V19\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"V19 Update 4\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"SIMOCODE ES V17","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SIMOCODE ES V17\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"*\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"SIMOCODE ES V18","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SIMOCODE ES V18\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"*\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"SIMOCODE ES V19","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SIMOCODE ES V19\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"*\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"SIMOTION SCOUT TIA V5.4","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SIMOTION SCOUT TIA V5.4\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"*\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"SIMOTION SCOUT TIA V5.5","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SIMOTION SCOUT TIA V5.5\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"*\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"SIMOTION SCOUT TIA V5.6","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SIMOTION SCOUT TIA V5.6\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"V5.6 SP1 HF7\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"SINAMICS Startdrive V17","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SINAMICS Startdrive V17\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"*\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"SINAMICS Startdrive V18","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SINAMICS Startdrive V18\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"*\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"SINAMICS Startdrive V19","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SINAMICS Startdrive V19\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"*\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"SIRIUS Safety ES V17 (TIA Portal)","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SIRIUS Safety ES V17 (TIA Portal)\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"*\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"SIRIUS Safety ES V18 (TIA Portal)","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SIRIUS Safety ES V18 (TIA Portal)\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"*\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"SIRIUS Safety ES V19 (TIA Portal)","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SIRIUS Safety ES V19 (TIA Portal)\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"*\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"SIRIUS Soft Starter ES V17 (TIA Portal)","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SIRIUS Soft Starter ES V17 (TIA Portal)\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"*\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"SIRIUS Soft Starter ES V18 (TIA Portal)","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SIRIUS Soft Starter ES V18 (TIA Portal)\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"*\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"SIRIUS Soft Starter ES V19 (TIA Portal)","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"SIRIUS Soft Starter ES V19 (TIA Portal)\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"*\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"TIA Portal Cloud V17","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"TIA Portal Cloud V17\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"*\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"TIA Portal Cloud V18","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"TIA Portal Cloud V18\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"*\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"},{"ecosystem":"Vendor product","name":"TIA Portal Cloud V19","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Siemens\",\n                    \"product\": \"TIA Portal Cloud V19\",\n                    \"versions\": [\n                        {\n                            \"status\": \"affected\",\n                            \"version\": \"0\",\n                            \"lessThan\": \"V5.2.1.1\",\n                            \"versionType\": \"custom\"\n                        }\n                    ],\n                    \"defaultStatus\": \"unknown\"\n                }"}],"metrics":[{"system":"CVSS 3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","score":7.3,"severity":"HIGH"},{"system":"CVSS 4.0","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","score":7,"severity":"HIGH"}],"references":["https://cert-portal.siemens.com/productcert/html/ssa-392859.html"],"sourceUrl":"https://www.cve.org/CVERecord?id=CVE-2024-52051","license":"CVE Program Terms of Use","key":"cve-program:CVE-2024-52051","identifiers":["CVE-2024-52051"]},"retained":false,"historicalAffected":[]}],"coverage":[{"source":"cisa-kev:global","scope":"Complete CISA KEV catalog; all vendors. Missing entries do not establish absence of exploitation.","generation":"2026-11-10T09:21:39.5670180+00:00","complete":true,"records":1773,"lastAttemptAt":"2026-11-10T09:21:39.567018+00:00","lastSuccessAt":"2026-11-10T09:21:39.7230126+00:00","error":null,"lastVerifiedAt":"2026-11-10T09:21:39.7230148+00:00","snapshotPublishedAt":null,"importing":false,"stagedRecords":0,"checkedIdentifiers":null,"expectedIdentifiers":null,"failedIdentifiers":null},{"source":"cve-program","scope":"Official CVE Program baseline and cumulative hourly delta; all vendors, published and rejected records","generation":"cve-8859cf40d4337e24bd2f258cc7778fbad01bb24c79d057aaf34cf1dfc6f8917d-8bdcdeeb414e06ff50ed637d818ac25d52680d19f71fc0ebe3f4c4b3f836ed38","complete":true,"records":421927,"lastAttemptAt":"2026-11-10T09:21:38.2251552+00:00","lastSuccessAt":"2026-11-10T09:21:38.1064889+00:00","error":null,"lastVerifiedAt":"2026-11-10T09:21:38.2251552+00:00","snapshotPublishedAt":"2026-11-10T09:20:43+00:00","importing":false,"stagedRecords":0,"checkedIdentifiers":null,"expectedIdentifiers":null,"failedIdentifiers":null},{"source":"euvd","scope":"Rolling EUVD lookups of CVE aliases in current public OSV archives; 500 identifiers per refresh, rechecked after 48 hours. Not a global EUVD catalog. Successful not-found lookups count as checked; they do not imply withdrawal or safety. No reader inventory is sent.","generation":"enrichment-2e6a476534094233b48f2f0b6da5cf35","complete":true,"records":13689,"lastAttemptAt":"2026-11-10T09:22:06.7603645+00:00","lastSuccessAt":"2026-11-10T06:05:35.03+00:00","error":null,"lastVerifiedAt":"2026-11-10T06:05:35.03+00:00","snapshotPublishedAt":null,"importing":false,"stagedRecords":0,"checkedIdentifiers":13742,"expectedIdentifiers":13742,"failedIdentifiers":0},{"source":"first-epss:nuget","scope":"FIRST EPSS for explicit CVE aliases in the collected public NuGet archive. Not a global EPSS backfill.","generation":"2026-11-10T09:21:39.5670180+00:00","complete":true,"records":1096,"lastAttemptAt":"2026-11-10T09:21:39.567018+00:00","lastSuccessAt":"2026-11-10T09:21:39.7239823+00:00","error":null,"lastVerifiedAt":"2026-11-10T09:21:39.7239826+00:00","snapshotPublishedAt":null,"importing":false,"stagedRecords":0,"checkedIdentifiers":null,"expectedIdentifiers":null,"failedIdentifiers":null},{"source":"nvd","scope":"Rolling NVD lookups of CVE aliases in current public OSV archives; 500 identifiers per refresh, rechecked after 48 hours. Not a global NVD catalog. Successful not-found lookups count as checked; they do not imply withdrawal or safety. No reader inventory is sent.","generation":"enrichment-31ba7927d759462ab5120f3eef3ca629","complete":false,"records":13695,"lastAttemptAt":"2026-11-10T09:22:06.1277445+00:00","lastSuccessAt":"2026-11-10T09:22:06.124+00:00","error":"100 identifier lookups failed; latest failures include request timeout. Other identifiers were checked independently.","lastVerifiedAt":"2026-11-10T09:22:06.124+00:00","snapshotPublishedAt":null,"importing":false,"stagedRecords":0,"checkedIdentifiers":13642,"expectedIdentifiers":13742,"failedIdentifiers":100},{"source":"osv:Go","scope":"Complete OSV Go ecosystem archive, including withdrawn and malicious-package source records; statement counts are not unique CVE counts","generation":"go-cdffb4589856378aa42e8d1bd4a6c74e27a180d8160bf764c44715ef760f0a62","complete":true,"records":9932,"lastAttemptAt":"2026-11-10T09:21:39.3678777+00:00","lastSuccessAt":"2026-11-10T00:04:19.8260565+00:00","error":null,"lastVerifiedAt":"2026-11-10T09:21:39.3678777+00:00","snapshotPublishedAt":"2026-11-09T23:48:01+00:00","importing":false,"stagedRecords":0,"checkedIdentifiers":null,"expectedIdentifiers":null,"failedIdentifiers":null},{"source":"osv:NuGet","scope":"Complete OSV NuGet ecosystem archive, including GitHub Advisory Database records; NuGet version matching only","generation":"nuget-26503967ae4379db8f374089589d6e03fb15bd31f820c9e992aaf93840c2236c","complete":true,"records":1971,"lastAttemptAt":"2026-11-10T09:21:39.1274719+00:00","lastSuccessAt":"2026-11-09T21:02:20.472473+00:00","error":null,"lastVerifiedAt":"2026-11-10T09:21:39.1274719+00:00","snapshotPublishedAt":"2026-11-09T20:18:18+00:00","importing":false,"stagedRecords":0,"checkedIdentifiers":null,"expectedIdentifiers":null,"failedIdentifiers":null},{"source":"osv:crates.io","scope":"Complete OSV crates.io ecosystem archive, including withdrawn and malicious-package source records; statement counts are not unique CVE counts","generation":"crates.io-94169eec81ea3989aa551092397ff34ae53c104b4a6ce646e1524452e4ab2a39","complete":true,"records":3065,"lastAttemptAt":"2026-11-10T09:21:39.5260038+00:00","lastSuccessAt":"2026-11-10T08:04:45.5923716+00:00","error":null,"lastVerifiedAt":"2026-11-10T09:21:39.5260038+00:00","snapshotPublishedAt":"2026-11-10T06:48:01+00:00","importing":false,"stagedRecords":0,"checkedIdentifiers":null,"expectedIdentifiers":null,"failedIdentifiers":null},{"source":"osv:npm","scope":"Complete OSV npm ecosystem archive, including withdrawn and malicious-package source records; statement counts are not unique CVE counts","generation":"npm-4331051b0b2d4ccdbdca3aa196b0be3818a465064a4b18dde4cf39c2250eb490","complete":true,"records":231599,"lastAttemptAt":"2026-11-10T09:21:39.251251+00:00","lastSuccessAt":"2026-11-10T08:04:37.1757322+00:00","error":null,"lastVerifiedAt":"2026-11-10T09:21:39.251251+00:00","snapshotPublishedAt":"2026-11-10T07:33:02+00:00","importing":false,"stagedRecords":0,"checkedIdentifiers":null,"expectedIdentifiers":null,"failedIdentifiers":null}]}