{"id":"CVE-2026-101153","revision":"1848bf1a44ff435e8c2a7d158ce2c03e","records":[{"revision":"1848bf1a44ff435e8c2a7d158ce2c03e","observedAt":"2026-10-23T15:48:27.903+00:00","statement":{"source":"cve-program","id":"CVE-2026-101153","aliases":[],"title":"Security Advisory 0188","description":"On affected versions of CloudVision Portal (on-premises) or CloudVision Sensor, a path traversal vulnerability exists. An authenticated user with sufficient high privileges could exploit this to extract unintended data from the Sensor.","state":0,"publishedAt":"2026-10-06T19:38:07.896+00:00","modifiedAt":"2026-10-06T19:49:31.675+00:00","affected":[{"ecosystem":"Vendor product","name":"CloudVision Portal","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Arista Networks\",\n                    \"product\": \"CloudVision Portal\",\n                    \"platforms\": [\n                        \"CloudVision Portal, virtual appliance or physical appliance\"\n                    ],\n                    \"defaultStatus\": \"unaffected\",\n                    \"versions\": [\n                        {\n                            \"version\": \"2026.2.0\",\n                            \"status\": \"affected\",\n                            \"versionType\": \"custom\"\n                        },\n                        {\n                            \"version\": \"2026.1.0\",\n                            \"lessThanOrEqual\": \"2026.1.2\",\n                            \"status\": \"affected\",\n                            \"versionType\": \"custom\"\n                        },\n                        {\n                            \"version\": \"2025.3.0\",\n                            \"lessThanOrEqual\": \"2025.3.3\",\n                            \"status\": \"affected\",\n                            \"versionType\": \"custom\"\n                        },\n                        {\n                            \"version\": \"2025.2.0\",\n                            \"lessThanOrEqual\": \"2025.2.3\",\n                            \"status\": \"affected\",\n                            \"versionType\": \"custom\"\n                        },\n                        {\n                            \"version\": \"2025.1.0\",\n                            \"lessThanOrEqual\": \"2025.1.4\",\n                            \"status\": \"affected\",\n                            \"versionType\": \"custom\"\n                        },\n                        {\n                            \"version\": \"2024.3.0\",\n                            \"lessThanOrEqual\": \"2024.3.3\",\n                            \"status\": \"affected\",\n                            \"versionType\": \"custom\"\n                        }\n                    ]\n                }"},{"ecosystem":"Vendor product","name":"CloudVision Sensor","ranges":[],"versions":[],"rawVersionEvidence":"{\n                    \"vendor\": \"Arista Networks\",\n                    \"product\": \"CloudVision Sensor\",\n                    \"platforms\": [\n                        \"CloudVision Sensor\"\n                    ],\n                    \"defaultStatus\": \"unaffected\",\n                    \"versions\": [\n                        {\n                            \"version\": \"1.4.0\",\n                            \"lessThanOrEqual\": \"1.4.2\",\n                            \"status\": \"affected\",\n                            \"versionType\": \"custom\"\n                        },\n                        {\n                            \"version\": \"1.3.0\",\n                            \"lessThanOrEqual\": \"1.3.1\",\n                            \"status\": \"affected\",\n                            \"versionType\": \"custom\"\n                        },\n                        {\n                            \"version\": \"1.0.0\",\n                            \"lessThan\": \"1.3.0\",\n                            \"status\": \"affected\",\n                            \"versionType\": \"custom\"\n                        }\n                    ]\n                }"}],"metrics":[{"system":"CVSS 3.1","vector":"CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H","score":8,"severity":"HIGH"},{"system":"CVSS 4.0","vector":"CVSS:4.0/AV:N/AC:H/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H","score":7.2,"severity":"HIGH"}],"references":["https://www.arista.com/en/support/advisories-notices/security-advisory/24804-security-advisory-0188"],"sourceUrl":"https://www.cve.org/CVERecord?id=CVE-2026-101153","license":"CVE Program Terms of Use","key":"cve-program:CVE-2026-101153","identifiers":["CVE-2026-101153"]},"retained":false,"historicalAffected":[]}],"coverage":[]}