{"id":"EUVD-2025-8034","enisaUuid":"768fe5bf-229a-359b-b90c-d8a574d3340f","description":"A security issue was discovered in  ingress-nginx https://github.com/kubernetes/ingress-nginx  where the `auth-tls-match-cn` Ingress annotation can be used to inject configuration into nginx. This can lead to arbitrary code execution in the context of the ingress-nginx controller, and disclosure of Secrets accessible to the controller. (Note that in the default installation, the controller can access all Secrets cluster-wide.)","datePublished":"Mar 24, 2025, 11:29:05 PM","dateUpdated":"Feb 26, 2026, 7:09:14 PM","baseScore":8.8,"baseScoreVersion":"3.1","baseScoreVector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","references":"https://github.com/kubernetes/kubernetes/issues/131007\n","aliases":"CVE-2025-1097\nGHSA-823x-fv5p-h7hw\n","assigner":"kubernetes","epss":36.96,"enisaIdProduct":[{"id":"90a46b8b-4062-3cd4-9f6c-a63866d752aa","product":{"name":"ingress-nginx","vendor":{"name":"Kubernetes"}},"product_version":"1.12.0"},{"id":"f5ad51d9-d4ca-3934-acb0-c22f8806ee33","product":{"name":"ingress-nginx","vendor":{"name":"Kubernetes"}},"product_version":"0 ≤1.11.4"}],"enisaIdVendor":[{"id":"b0ec8a54-6e5e-364a-8175-aed3a10abcdf","vendor":{"name":"Kubernetes"}}],"enisaIdVulnerability":[{"id":"a02c0b9a-b33c-3951-9559-f22d6d5893b7","vulnerability":{"id":"GHSA-823x-fv5p-h7hw","description":"ngress-nginx controller - configuration injection via unsanitized auth-tls-match-cn annotation","datePublished":"Mar 25, 2025, 12:30:26 AM","dateUpdated":"Nov 3, 2025, 9:33:13 PM","baseScore":0.0,"references":"https://nvd.nist.gov/vuln/detail/CVE-2025-1097\nhttps://github.com/kubernetes/kubernetes/issues/131007\nhttps://github.com/kubernetes/ingress-nginx\nhttps://github.com/kubernetes/ingress-nginx/releases/tag/controller-v1.11.5\nhttps://github.com/kubernetes/ingress-nginx/releases/tag/controller-v1.12.1\nhttps://groups.google.com/g/kubernetes-security-announce/c/2qa9DFtN0cQ\nhttps://security.netapp.com/advisory/ntap-20250328-0008\n","enisa_id":"EUVD-2025-8034\n","aliases":"GHSA-823x-fv5p-h7hw\nCVE-2025-1097\n","epss":0.0,"dataProcessed":"Nov 15, 2026, 2:42:04 AM","vulnerabilityProduct":[],"vulnerabilityVendor":[]}},{"id":"d103609f-21f7-3d6c-9598-a5c4b56b2392","vulnerability":{"id":"CVE-2025-1097","description":"A security issue was discovered in  ingress-nginx https://github.com/kubernetes/ingress-nginx  where the `auth-tls-match-cn` Ingress annotation can be used to inject configuration into nginx. This can lead to arbitrary code execution in the context of the ingress-nginx controller, and disclosure of Secrets accessible to the controller. (Note that in the default installation, the controller can access all Secrets cluster-wide.)","datePublished":"Mar 24, 2025, 11:29:05 PM","dateUpdated":"Feb 26, 2026, 7:09:14 PM","status":"PUBLISHED","baseScore":8.8,"baseScoreVersion":"3.1","baseScoreVector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","references":"https://github.com/kubernetes/kubernetes/issues/131007\n","enisa_id":"EUVD-2025-8034\n","assigner":"kubernetes","epss":36.96,"dataProcessed":"Nov 19, 2026, 7:18:01 AM","vulnerabilityProduct":[{"id":"0bb04f3e-7bf3-37af-b378-df7aa18684e4","product":{"name":"ingress-nginx","vendor":{"name":"Kubernetes"}},"product_version":"1.12.0"},{"id":"5fea1172-c580-35c4-b157-888649542bf3","product":{"name":"ingress-nginx","vendor":{"name":"Kubernetes"}},"product_version":"0 ≤1.11.4"}],"vulnerabilityVendor":[{"id":"213ec998-f0bd-33e2-9c07-c8810c930f86","vendor":{"name":"Kubernetes"}}]}}],"enisaIdAdvisory":[{"id":"06742db6-0275-331c-b043-aabea8b597c7","advisory":{"id":"NCSC-2025-0106","description":"Kwetsbaarheden verholpen in Siemens producten","datePublished":"Apr 8, 2025, 1:57:11 PM","dateUpdated":"Apr 8, 2025, 1:57:11 PM","baseScore":0.0,"references":"","aliases":"CVE-2022-21658\nCVE-2023-2975\nCVE-2023-3446\nCVE-2023-3817\nCVE-2023-4807\nCVE-2023-5363\nCVE-2023-5678\nCVE-2023-7104\nCVE-2024-0056\nCVE-2024-0232\nCVE-2024-0727\nCVE-2024-5535\nCVE-2024-9143\nCVE-2024-21319\nCVE-2024-23814\nCVE-2024-30105\nCVE-2024-41788\nCVE-2024-41789\nCVE-2024-41790\nCVE-2024-41791\nCVE-2024-41792\nCVE-2024-41793\nCVE-2024-41794\nCVE-2024-41795\nCVE-2024-41796\nCVE-2024-54091\nCVE-2024-54092\nCVE-2025-30280\nCVE-2025-1097\nCVE-2025-24514\nCVE-2025-24513\nCVE-2025-1974\nCVE-2025-1098\nCVE-2025-29999\nCVE-2025-30000\n","source":{"id":19,"name":"csaf_ncscnl"},"advisoryProduct":[{"id":"0521d7d6-d229-311e-b284-1b71c11663ba","product":{"name":"SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)","vendor":{"name":"Siemens"}}},{"id":"0555fde4-edea-37ba-b97d-80febbf13ff7","product":{"name":"Mendix Runtime","vendor":{"name":"Siemens"}}},{"id":"0657b3b6-6fb5-3a35-8593-7cd335a37853","product":{"name":"SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants)","vendor":{"name":"Siemens"}}},{"id":"101cec8a-1f1a-3813-978c-058ff8021406","product":{"name":"SINUMERIK 840D sl","vendor":{"name":"Siemens"}}},{"id":"108a6389-d39c-3aa5-b5a0-15f49c89f9cd","product":{"name":"Industrial Edge Device Kit - arm64 V1.17","vendor":{"name":"Siemens"}}},{"id":"141722a5-a326-372d-a120-873f5b5f535a","product":{"name":"Siemens Simatic S7-1500 Tm Mfp","vendor":{"name":"Siemens"}}},{"id":"1af6e668-7ee4-303e-817a-54182dc84390","product":{"name":"vers:unknown/\u003cv9.24.34","vendor":{"name":"Siemens"}}},{"id":"1b5d35bc-bd73-30eb-996f-fd55a10d4ec3","product":{"name":"Industrial Edge Device Kit - arm64 V1.18","vendor":{"name":"Siemens"}}},{"id":"1b923b82-dac6-3221-8eec-d4977041303c","product":{"name":"SIPLUS ET 200SP IM 155-6 PN HF TX RAIL","vendor":{"name":"Siemens"}}},{"id":"22fff424-9769-3de2-80d2-38445a8cef28","product":{"name":"SIMATIC ET 200S IM 151-8F PN/DP CPU","vendor":{"name":"Siemens"}}},{"id":"26342835-3d51-3914-83e1-1c101fb78da1","product":{"name":"SIMATIC ET 200MP IM 155-5 PN ST","vendor":{"name":"Siemens"}}},{"id":"26b7469e-4d51-3064-b996-1bc52b9340d8","product":{"name":"SIPLUS ET 200S IM 151-8 PN/DP CPU","vendor":{"name":"Siemens"}}},{"id":"32fa33cd-5b1f-3c88-b1fd-28793c9f06ff","product":{"name":"Industrial Edge Device Kit - x86-64 V1.17","vendor":{"name":"Siemens"}}},{"id":"335e5627-b99c-3ca6-aca0-d411a91f39cb","product":{"name":"SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)","vendor":{"name":"Siemens"}}},{"id":"358bf773-308d-378e-99e8-ab87825696ca","product":{"name":"SIPLUS ET 200MP IM 155-5 PN HF","vendor":{"name":"Siemens"}}},{"id":"36f35b2a-4c71-3a86-955f-c66a6f71c8aa","product":{"name":"Industrial Edge Device Kit - x86-64 V1.19","vendor":{"name":"Siemens"}}},{"id":"37080bff-5373-395f-86cf-431531ad35d5","product":{"name":"SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants)","vendor":{"name":"Siemens"}}},{"id":"399c585c-1f9a-324d-b8fd-dca1fd85fa5a","product":{"name":"Siemens License Server (SLS)","vendor":{"name":"Siemens"}}},{"id":"3d436781-dabf-3479-954f-1550aa7b0f83","product":{"name":"SIPLUS ET 200MP IM 155-5 PN ST TX RAIL","vendor":{"name":"Siemens"}}},{"id":"3f0a8699-dba4-3ee1-8b65-d19cb86978d7","product":{"name":"SIMATIC ET 200SP CPU 1512SP-1 PN","vendor":{"name":"Siemens"}}},{"id":"44323d50-7d20-3c72-8f57-0ba3fb66b45b","product":{"name":"SIMATIC ET 200SP CPU 1510SP F-1 PN","vendor":{"name":"Siemens"}}},{"id":"45d3c078-7b72-30c8-abd5-1be133d93423","product":{"name":"Industrial Edge Device Kit - x86-64 V1.20","vendor":{"name":"Siemens"}}},{"id":"4719df9c-238e-3805-a583-9632244b06f6","product":{"name":"SIPLUS ET 200S IM151-3 PN HF","vendor":{"name":"Siemens"}}},{"id":"4c5cfb33-a310-32aa-925e-a2d1bca05c40","product":{"name":"SIMATIC CFU PA","vendor":{"name":"Siemens"}}},{"id":"4d787ec7-42a3-344e-a25d-49bf9c4c742f","product":{"name":"SIDOOR ATE530G COATED","vendor":{"name":"Siemens"}}},{"id":"5ac123c8-5a06-340c-8401-1dd08225c75d","product":{"name":"SIDOOR ATD430W","vendor":{"name":"Siemens"}}},{"id":"5d57cff0-3537-3dc4-886e-6e2e7afc5ca4","product":{"name":"Industrial Edge Device Kit - arm64 V1.19","vendor":{"name":"Siemens"}}},{"id":"5f4ee9d2-e86c-354b-a709-eb950c8ff48d","product":{"name":"SIPLUS ET 200MP IM 155-5 PN ST","vendor":{"name":"Siemens"}}},{"id":"607a1049-6232-3f3a-bd53-15234f6c2fcd","product":{"name":"SIMATIC ET 200MP IM 155-5 PN BA","vendor":{"name":"Siemens"}}},{"id":"66e2d3d5-ce3d-3940-9e1a-e6396bca5a37","product":{"name":"SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL","vendor":{"name":"Siemens"}}},{"id":"6c9be3aa-0393-3fdd-8b46-1a09259603de","product":{"name":"Industrial Edge Own Device (IEOD)","vendor":{"name":"Siemens"}}},{"id":"6cc9f373-b306-3fa8-bd91-a8e4ee2c1c0f","product":{"name":"SIMATIC ET 200S IM 151-3 PN ST","vendor":{"name":"Siemens"}}},{"id":"6fb77c57-3a1d-3ff1-86eb-4eca9a8b6f8b","product":{"name":"SIPLUS ET 200SP IM 155-6 PN HF","vendor":{"name":"Siemens"}}},{"id":"740094d1-8932-3c62-92a3-0adfff0cd01e","product":{"name":"SIPLUS ET 200M IM 153-4 PN IO ST","vendor":{"name":"Siemens"}}},{"id":"75f7863d-b9c5-3ee4-9dbc-a6772768bb49","product":{"name":"SIMATIC ET 200SP IM 155-6 PN HS","vendor":{"name":"Siemens"}}},{"id":"7687027b-419a-3c11-89c5-1d8710490900","product":{"name":"SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL","vendor":{"name":"Siemens"}}},{"id":"78b6fe7a-8fe4-383b-b915-41991fb8b3ab","product":{"name":"SIMATIC ET 200S IM 151-3 PN HS","vendor":{"name":"Siemens"}}},{"id":"811371c1-f00d-32cf-968b-bf6860dac376","product":{"name":"SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL","vendor":{"name":"Siemens"}}},{"id":"8581ff75-d876-306c-94f3-c86677f6ef46","product":{"name":"Industrial Edge Device Kit - arm64 V1.21","vendor":{"name":"Siemens"}}},{"id":"8a1b8686-ba72-365f-960f-412cc50a5356","product":{"name":"SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)","vendor":{"name":"Siemens"}}},{"id":"91d19d61-a6d5-3df2-bdf2-4e17be67347d","product":{"name":"SIWAREX WP522 ST","vendor":{"name":"Siemens"}}},{"id":"93a6374f-51a5-33ae-97ad-566c25695226","product":{"name":"Industrial Edge Device Kit - arm64 V1.20","vendor":{"name":"Siemens"}}},{"id":"94c21c38-e02a-30a3-971a-33bd89403e8c","product":{"name":"Mendix Runtime V10","vendor":{"name":"Siemens"}}},{"id":"96a42d4b-2c9f-39df-ad92-0607e970abac","product":{"name":"SIMATIC ET 200M IM 153-4 PN IO ST","vendor":{"name":"Siemens"}}},{"id":"96e55824-d708-382c-9da6-03a938dd9c3b","product":{"name":"SIPLUS ET 200SP IM 155-6 PN ST TX RAIL","vendor":{"name":"Siemens"}}},{"id":"971611a8-42ea-3f1a-bce1-716112b8e818","product":{"name":"SIMATIC ET 200S IM 151-8 PN/DP CPU","vendor":{"name":"Siemens"}}},{"id":"97a742a8-00b2-38fc-8067-186f30503aa0","product":{"name":"Industrial Edge Device Kit - x86-64 V1.18","vendor":{"name":"Siemens"}}},{"id":"97aa8200-592b-39ba-89fc-5a967c27d7cf","product":{"name":"SIMOCODE pro V PROFINET","vendor":{"name":"Siemens"}}},{"id":"9a93a3c1-fc6a-3a11-b182-a96b9348e007","product":{"name":"Mendix Runtime V10.6","vendor":{"name":"Siemens"}}},{"id":"9ac61d95-4d27-3d43-ac21-61d9ef360542","product":{"name":"SIPLUS ET 200S IM 151-8F PN/DP CPU","vendor":{"name":"Siemens"}}},{"id":"9aeccbad-e13b-32b1-adf9-2985f23eddfd","product":{"name":"SIWAREX WP231","vendor":{"name":"Siemens"}}},{"id":"9e76fd6c-1624-3017-9521-a06d46dce0f8","product":{"name":"Solid Edge SE2024","vendor":{"name":"Siemens"}}},{"id":"a36dba3d-bf15-3870-bbda-1e670fed4e41","product":{"name":"SIMATIC ET 200SP CPU 1512SP F-1 PN","vendor":{"name":"Siemens"}}},{"id":"a7d1eaac-733b-3aa0-880d-c1ff64432f09","product":{"name":"Mendix Runtime V9","vendor":{"name":"Siemens"}}},{"id":"a82447f3-6d20-373d-bc85-53f2dcde618b","product":{"name":"SIMATIC ET 200MP IM 155-5 PN HF","vendor":{"name":"Siemens"}}},{"id":"a8c9bb07-0f94-3912-bf72-ab02a89982ee","product":{"name":"SIWAREX WP251","vendor":{"name":"Siemens"}}},{"id":"aa3ba595-8cc0-32e0-a6d4-608014d742e2","product":{"name":"Mendix Runtime V10.18","vendor":{"name":"Siemens"}}},{"id":"ac28ccaa-83f3-3e19-b130-a2a5dc78e4f2","product":{"name":"Siemens Telecontrol Server Basic","vendor":{"name":"Siemens"}}},{"id":"ac5b1cae-fba4-3c33-90ce-fd27ac960dd5","product":{"name":"SIPLUS ET 200SP IM 155-6 PN ST","vendor":{"name":"Siemens"}}},{"id":"af18ae65-d2cc-3898-b318-ca2e148b642d","product":{"name":"SIMATIC ET 200SP IM 155-6 PN HF","vendor":{"name":"Siemens"}}},{"id":"b365efce-dda5-31da-8e75-0d248b375452","product":{"name":"Mendix Runtime V8","vendor":{"name":"Siemens"}}},{"id":"b38e7483-340c-324f-98ab-45fa6d106a17","product":{"name":"Solid Edge SE2025","vendor":{"name":"Siemens"}}},{"id":"b6423641-22b9-3a3d-a464-6b2f226f2b2b","product":{"name":"SIMATIC ET 200SP IM 155-6 MF HF","vendor":{"name":"Siemens"}}},{"id":"b7cecc09-25c2-372e-8d52-d642f01c55e8","product":{"name":"SIMATIC ET 200SP IM 155-6 PN BA","vendor":{"name":"Siemens"}}},{"id":"bdd84963-066e-3412-9454-6c86559588b7","product":{"name":"SIMATIC ET 200SP CPU 1510SP-1 PN","vendor":{"name":"Siemens"}}},{"id":"c59d4493-8336-331c-b8a7-680d2780bd6e","product":{"name":"SIMATIC ET 200SP IM 155-6 PN ST","vendor":{"name":"Siemens"}}},{"id":"c691bf37-b72b-30af-ba63-c3dec023f419","product":{"name":"Industrial Edge Device Kit - x86-64 V1.21","vendor":{"name":"Siemens"}}},{"id":"c93c7daa-0d85-3da3-867d-7f2563774519","product":{"name":"License Server","vendor":{"name":"Siemens"}}},{"id":"cc3625d5-07af-3980-a15d-1dbe5c8e8f54","product":{"name":"SIPLUS ET 200SP CPU 1512SP F-1 PN","vendor":{"name":"Siemens"}}},{"id":"cd84f2a8-8dd7-3c4d-a6ca-ca903924ea75","product":{"name":"Mendix Runtime V10.12","vendor":{"name":"Siemens"}}},{"id":"dc53b2ef-dac1-3e1e-a305-c81f059b03e2","product":{"name":"SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)","vendor":{"name":"Siemens"}}},{"id":"dfbe0ec2-24ff-3867-ad47-18667d5ac37a","product":{"name":"SIWAREX WP521 ST","vendor":{"name":"Siemens"}}},{"id":"e3ad65c8-8e7e-3677-a940-a749d7a98120","product":{"name":"SINEC Network Management System","vendor":{"name":"Siemens"}}},{"id":"e45d3ffc-2493-3154-b122-d94c52cd6990","product":{"name":"SIPLUS ET 200S IM151-3 PN ST","vendor":{"name":"Siemens"}}},{"id":"eaaa61de-0fc8-3e22-9cae-c1489ca176a7","product":{"name":"SIWAREX WP241","vendor":{"name":"Siemens"}}},{"id":"ebef322f-89a6-35d5-8449-6faacf59bef1","product":{"name":"SIMATIC ET 200AL IM 157-1 PN","vendor":{"name":"Siemens"}}},{"id":"ec6f7c74-f185-3c77-996c-9bb010a5a5f5","product":{"name":"SIMATIC ET 200S IM 151-3 PN FO","vendor":{"name":"Siemens"}}},{"id":"ed51029c-3373-3e2e-9e90-5eb9e2150e16","product":{"name":"solid_edge_se2024","vendor":{"name":"Siemens"}}},{"id":"f31c2633-d02c-3655-a3bd-6dac51e50f8a","product":{"name":"SIMATIC ET 200M IM 153-4 PN IO HF","vendor":{"name":"Siemens"}}},{"id":"f38b9f00-d17d-3fc8-8edd-5d5896c2c666","product":{"name":"Solid Edge","vendor":{"name":"Siemens"}}},{"id":"f5690225-cd06-35cf-a5d1-d2d6c6760a18","product":{"name":"SIPLUS ET 200SP IM 155-6 PN ST BA","vendor":{"name":"Siemens"}}},{"id":"f63fc21c-f058-382f-a758-c77ffaa083b4","product":{"name":"SIPLUS HCS4200 CIM4210","vendor":{"name":"Siemens"}}},{"id":"f68f9ae1-5433-3831-8c45-a4e6b3c96f24","product":{"name":"SIMATIC ET 200S IM 151-3 PN HF","vendor":{"name":"Siemens"}}},{"id":"f6b5469e-ce18-386a-aa67-173ff198cc63","product":{"name":"SIPLUS ET 200M IM 153-4 PN IO HF","vendor":{"name":"Siemens"}}},{"id":"fa331207-c821-3825-a519-dbecb2c50107","product":{"name":"SIMATIC CFU DIQ","vendor":{"name":"Siemens"}}},{"id":"fee4b133-efe7-3707-b38a-ca482e52492d","product":{"name":"SIDOOR ATE530S COATED","vendor":{"name":"Siemens"}}},{"id":"ff7bbac5-15d9-3ecf-be58-5ba51d521138","product":{"name":"SENTRON 7KT PAC1260 Data Manager","vendor":{"name":"Siemens"}}}]}},{"id":"27f60ec1-fe14-3d82-96fe-506edb15bb9b","advisory":{"id":"SSA-817234","description":"SSA-817234: Multiple Kubernetes Ingress NGINX Controller Vulnerabilities in Insights Hub Private Cloud","summary":"Insights Hub Private Cloud is affected by multiple vulnerabilities in Ingress NGINX Controller for Kubernetes. These vulnerabilities could lead to arbitrary code execution in the context of the \ningress-nginx controller, or disclosure of Secrets accessible to the controller, or denial of service condition.\nSiemens has released a new version for Insights Hub Private Cloud and recommends to update to the latest version.","datePublished":"Apr 8, 2025, 12:00:00 AM","dateUpdated":"Apr 8, 2025, 12:00:00 AM","baseScore":0.0,"references":"https://cert-portal.siemens.com/productcert/html/ssa-817234.html\nhttps://cert-portal.siemens.com/productcert/csaf/ssa-817234.json\n","aliases":"CVE-2025-1097\nCVE-2025-1098\nCVE-2025-1974\nCVE-2025-24513\nCVE-2025-24514\n","source":{"id":7,"name":"csaf_siemens"},"advisoryProduct":[{"id":"3c54902b-b1e7-3c0c-b1ec-3cadde182343","product":{"name":"Insights Hub Private Cloud","vendor":{"name":"Siemens"}}}]}},{"id":"40edf76a-6c96-34bc-9c76-2948b512379a","advisory":{"id":"ICSA-25-100-05","description":"Siemens Insights Hub Private Cloud","summary":"Insights Hub Private Cloud is affected by multiple vulnerabilities in Ingress NGINX Controller for Kubernetes. These vulnerabilities could lead to arbitrary code execution in the context of the \ningress-nginx controller, or disclosure of Secrets accessible to the controller, or denial of service condition.\nSiemens has released a new version for Insights Hub Private Cloud and recommends to update to the latest version.","datePublished":"Apr 8, 2025, 12:00:00 AM","dateUpdated":"Apr 8, 2025, 12:00:00 AM","baseScore":0.0,"references":"https://cert-portal.siemens.com/productcert/csaf/ssa-817234.json\nhttps://cert-portal.siemens.com/productcert/html/ssa-817234.html\nhttps://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-100-05.json\nhttps://www.cisa.gov/news-events/ics-advisories/icsa-25-100-05\n","aliases":"CVE-2025-1097\nCVE-2025-1098\nCVE-2025-1974\nCVE-2025-24513\nCVE-2025-24514\n","source":{"id":6,"name":"csaf_cisa"},"advisoryProduct":[{"id":"ff145705-44df-3b37-9ce2-675c8ede4769","product":{"name":"Insights Hub Private Cloud","vendor":{"name":"Siemens"}}}]}},{"id":"69cd068f-3d22-3726-82ab-258b4b95f21d","advisory":{"id":"WID-SEC-W-2025-0629","description":"Ingress NGINX Controller für Kubernetes: Mehrere Schwachstellen","summary":"Ein entfernter, anonymer oder authentisierter Angreifer kann mehrere Schwachstellen im Ingress NGINX Controller für Kubernetes ausnutzen, um beliebigen Code auszuführen, vertrauliche Informationen offenzulegen und einen Denial-of-Service-Zustand zu verursachen.","datePublished":"Mar 24, 2025, 11:00:00 PM","dateUpdated":"Jan 15, 2026, 11:00:00 PM","baseScore":0.0,"references":"https://wid.cert-bund.de/.well-known/csaf/white/2025/wid-sec-w-2025-0629.json\nhttps://wid.cert-bund.de/portal/wid/securityadvisory?name\u003dWID-SEC-2025-0629\n","aliases":"CVE-2025-1097\nCVE-2025-1098\nCVE-2025-1974\nCVE-2025-24513\nCVE-2025-24514\n","source":{"id":8,"name":"csaf_certbund"},"advisoryProduct":[{"id":"1d00963e-34ac-3944-82cd-38173f08c064","product":{"name":"Ingress NGINX Controller 1.12.1","vendor":{"name":"open source"}}},{"id":"4fe4b46a-a216-30f3-97f9-4a4973d8f0a8","product":{"name":"IBM InfoSphere Information Server","vendor":{"name":"IBM"}}},{"id":"a5d3eed1-a967-35ae-917e-a0254202b672","product":{"name":"SUSE openSUSE","vendor":{"name":"SUSE"}}},{"id":"b0cb0edc-58e5-396a-9fb7-5b212d5593db","product":{"name":"Kubernetes","vendor":{"name":"Kubernetes"}}},{"id":"b4cd0722-cf5b-340b-b9c9-58bf8d1e7d55","product":{"name":"Ingress NGINX Controller 1.11.5","vendor":{"name":"open source"}}}]}},{"id":"8ac263ab-d3fe-380b-806c-f1cbdd0b76b3","advisory":{"id":"openSUSE-SU-2025:14937-1","description":"govulncheck-vulndb-0.0.20250327T184518-1.1 on GA media","summary":"govulncheck-vulndb-0.0.20250327T184518-1.1 on GA media","datePublished":"Mar 28, 2025, 12:00:00 AM","dateUpdated":"Sep 20, 2026, 9:30:09 PM","baseScore":0.0,"references":"https://ftp.suse.com/pub/projects/security/csaf/opensuse-su-2025_14937-1.json\nhttps://lists.opensuse.org/archives/list/security-announce@lists.opensuse.org/thread/NEVFAGUWHTVZSJTUAIU6C4S26DP2KIGB/\nhttps://lists.opensuse.org/archives/list/security-announce@lists.opensuse.org/thread/NEVFAGUWHTVZSJTUAIU6C4S26DP2KIGB/\nhttps://www.suse.com/security/cve/CVE-2024-25132/\nhttps://www.suse.com/security/cve/CVE-2024-53348/\nhttps://www.suse.com/security/cve/CVE-2024-53351/\nhttps://www.suse.com/security/cve/CVE-2024-7598/\nhttps://www.suse.com/security/cve/CVE-2024-7631/\nhttps://www.suse.com/security/cve/CVE-2024-9042/\nhttps://www.suse.com/security/cve/CVE-2024-9900/\nhttps://www.suse.com/security/cve/CVE-2025-1097/\nhttps://www.suse.com/security/cve/CVE-2025-1098/\nhttps://www.suse.com/security/cve/CVE-2025-1472/\nhttps://www.suse.com/security/cve/CVE-2025-1767/\nhttps://www.suse.com/security/cve/CVE-2025-1974/\nhttps://www.suse.com/security/cve/CVE-2025-24513/\nhttps://www.suse.com/security/cve/CVE-2025-24514/\nhttps://www.suse.com/security/cve/CVE-2025-24920/\nhttps://www.suse.com/security/cve/CVE-2025-25068/\nhttps://www.suse.com/security/cve/CVE-2025-25274/\nhttps://www.suse.com/security/cve/CVE-2025-27612/\nhttps://www.suse.com/security/cve/CVE-2025-27715/\nhttps://www.suse.com/security/cve/CVE-2025-27933/\nhttps://www.suse.com/security/cve/CVE-2025-29778/\nhttps://www.suse.com/security/cve/CVE-2025-29914/\nhttps://www.suse.com/security/cve/CVE-2025-29922/\nhttps://www.suse.com/security/cve/CVE-2025-29923/\nhttps://www.suse.com/security/cve/CVE-2025-30077/\nhttps://www.suse.com/security/cve/CVE-2025-30153/\nhttps://www.suse.com/security/cve/CVE-2025-30162/\nhttps://www.suse.com/security/cve/CVE-2025-30163/\nhttps://www.suse.com/security/cve/CVE-2025-30179/\nhttps://www.suse.com/security/cve/CVE-2025-30204/\n","aliases":"CVE-2024-25132\nCVE-2024-53348\nCVE-2024-53351\nCVE-2024-7598\nCVE-2024-7631\nCVE-2024-9042\nCVE-2024-9900\nCVE-2025-1097\nCVE-2025-1098\nCVE-2025-1472\nCVE-2025-1767\nCVE-2025-1974\nCVE-2025-24513\nCVE-2025-24514\nCVE-2025-24920\nCVE-2025-25068\nCVE-2025-25274\nCVE-2025-27612\nCVE-2025-27715\nCVE-2025-27933\nCVE-2025-29778\nCVE-2025-29914\nCVE-2025-29922\nCVE-2025-29923\nCVE-2025-30077\nCVE-2025-30153\nCVE-2025-30162\nCVE-2025-30163\nCVE-2025-30179\nCVE-2025-30204\n","source":{"id":21,"name":"csaf_opensuse"},"advisoryProduct":[{"id":"2691d1e6-cbe0-3cce-ae47-09578e609c87","product":{"name":"govulncheck-vulndb-0:0.0.20250327T184518-1.1.x86_64","vendor":{"name":"SUSE"}}},{"id":"4f68879d-48de-3120-95c6-539cffcfdb3a","product":{"name":"govulncheck-vulndb-0:0.0.20250327T184518-1.1.s390x","vendor":{"name":"SUSE"}}},{"id":"6d71a2f4-3f7a-3765-8d27-ef7f9def0564","product":{"name":"govulncheck-vulndb-0.0.20250327T184518-1.1.s390x","vendor":{"name":"SUSE"}}},{"id":"79a9ebea-0849-31f6-b766-f78d5854db55","product":{"name":"openSUSE Tumbleweed","vendor":{"name":"SUSE"}}},{"id":"7aaa3579-ccda-3f54-841e-41dffbde8473","product":{"name":"govulncheck-vulndb-0.0.20250327T184518-1.1.aarch64","vendor":{"name":"SUSE"}}},{"id":"ae59c10b-7ae2-3237-9183-9424079709bc","product":{"name":"govulncheck-vulndb-0.0.20250327T184518-1.1.x86_64","vendor":{"name":"SUSE"}}},{"id":"b8f796b1-c6f6-32e3-a4dc-c22dd9d84d73","product":{"name":"govulncheck-vulndb-0:0.0.20250327T184518-1.1.aarch64","vendor":{"name":"SUSE"}}},{"id":"e6861774-3e53-38b9-9bb2-b855689cefb7","product":{"name":"govulncheck-vulndb-0.0.20250327T184518-1.1.ppc64le","vendor":{"name":"SUSE"}}},{"id":"e872e122-92ce-36a5-a2f7-1bfe72dfe283","product":{"name":"govulncheck-vulndb-0:0.0.20250327T184518-1.1.ppc64le","vendor":{"name":"SUSE"}}}]}},{"id":"932d865f-60c4-3d99-9639-1eaa6b2458e4","advisory":{"id":"NCSC-2025-0095","description":"Kwetsbaarheden verholpen in Kubernetes Ingress NGINX Controller ","datePublished":"Mar 25, 2025, 7:13:08 AM","dateUpdated":"Mar 27, 2025, 2:41:30 PM","baseScore":0.0,"references":"","aliases":"CVE-2025-1974\nCVE-2025-1097\nCVE-2025-1098\nCVE-2025-24514\nCVE-2025-24513\n","source":{"id":19,"name":"csaf_ncscnl"},"advisoryProduct":[{"id":"60e62566-33f0-3a77-b2c9-c9492be556cd","product":{"name":"ingress-nginx","vendor":{"name":"Kubernetes"}}},{"id":"792907a2-7d04-3a19-b10f-5f807e0b70af","product":{"name":"vers:unknown/1.12.0","vendor":{"name":"Kubernetes"}}},{"id":"d9145c4c-0d3a-34d4-ba41-a2dfe6e9bab6","product":{"name":"vers:semver/\u003c\u003d1.11.4","vendor":{"name":"Kubernetes"}}}]}}]}