{"id":"EUVD-2026-18935","enisaUuid":"8fd98409-4fc8-3399-8661-4bcae0d9c0e1","description":"Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. Prior to versions 38.8.6, 39.8.1, 40.8.0, and 41.0.0-beta.8, on Windows, app.setLoginItemSettings({openAtLogin: true}) wrote the executable path to the Run registry key without quoting. If the app is installed to a path containing spaces, an attacker with write access to an ancestor directory may be able to cause a different executable to run at login instead of the intended app. On a default Windows install, standard system directories are protected against writes by standard users, so exploitation typically requires a non-standard install location. This issue has been patched in versions 38.8.6, 39.8.1, 40.8.0, and 41.0.0-beta.8.","datePublished":"Apr 3, 2026, 11:44:55 PM","dateUpdated":"Apr 6, 2026, 7:08:58 PM","baseScore":3.9,"baseScoreVersion":"3.1","baseScoreVector":"CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:L","references":"https://github.com/electron/electron/security/advisories/GHSA-jfqx-fxh3-c62j\n","aliases":"CVE-2026-34768\n","assigner":"GitHub_M","epss":0.14,"enisaIdProduct":[{"id":"28a14a83-e649-32e2-ac1c-5bdca2723dcc","product":{"name":"electron","vendor":{"name":"electron"}},"product_version":"41.0.0-alpha.1, \u003c 41.0.0-beta.8"},{"id":"640b5282-1c53-3358-9a1c-87a296a7181c","product":{"name":"electron","vendor":{"name":"electron"}},"product_version":"\u003c 38.8.6"},{"id":"66a7824c-cdea-3916-86f6-940ab0285d7d","product":{"name":"electron","vendor":{"name":"electron"}},"product_version":"39.0.0-alpha.1, \u003c 39.8.1"},{"id":"8c6079ef-9c56-3fac-864d-fecf53d06580","product":{"name":"electron","vendor":{"name":"electron"}},"product_version":"40.0.0-alpha.1, \u003c 40.8.0"}],"enisaIdVendor":[{"id":"c36b9312-b62a-3b92-991f-238279253170","vendor":{"name":"electron"}}],"enisaIdVulnerability":[{"id":"ad5529c2-066f-3e13-a557-991acd3c599a","vulnerability":{"id":"CVE-2026-34768","description":"Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. Prior to versions 38.8.6, 39.8.1, 40.8.0, and 41.0.0-beta.8, on Windows, app.setLoginItemSettings({openAtLogin: true}) wrote the executable path to the Run registry key without quoting. If the app is installed to a path containing spaces, an attacker with write access to an ancestor directory may be able to cause a different executable to run at login instead of the intended app. On a default Windows install, standard system directories are protected against writes by standard users, so exploitation typically requires a non-standard install location. This issue has been patched in versions 38.8.6, 39.8.1, 40.8.0, and 41.0.0-beta.8.","datePublished":"Apr 3, 2026, 11:44:55 PM","dateUpdated":"Apr 6, 2026, 7:08:58 PM","status":"PUBLISHED","baseScore":3.9,"baseScoreVersion":"3.1","baseScoreVector":"CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:L","references":"https://github.com/electron/electron/security/advisories/GHSA-jfqx-fxh3-c62j\n","enisa_id":"EUVD-2026-18935\n","assigner":"GitHub_M","epss":0.14,"dataProcessed":"Nov 21, 2026, 7:25:13 AM","vulnerabilityProduct":[{"id":"1a51748f-f262-3aaf-b69e-86280d149be5","product":{"name":"electron","vendor":{"name":"electron"}},"product_version":"\u003c 38.8.6"},{"id":"9de54bea-00b7-3ecc-b870-2a0a25ed868d","product":{"name":"electron","vendor":{"name":"electron"}},"product_version":"39.0.0-alpha.1, \u003c 39.8.1"},{"id":"c762f627-eb88-3f90-a3f3-ac594beabcae","product":{"name":"electron","vendor":{"name":"electron"}},"product_version":"40.0.0-alpha.1, \u003c 40.8.0"},{"id":"ee143a04-eb30-338a-91e0-7dafd18ca911","product":{"name":"electron","vendor":{"name":"electron"}},"product_version":"41.0.0-alpha.1, \u003c 41.0.0-beta.8"}],"vulnerabilityVendor":[{"id":"d17b7fd7-8824-3576-960d-2d958cddcedd","vendor":{"name":"electron"}}]}}],"enisaIdAdvisory":[]}