Public mode

No access to your tenant or devices. Every item links to its source. What this means

Sources need attention Customize Public modeDiscuss ChangeIntel on Discord

KNX Protocol Connection Authorization Option 1 · Vulnerability

CVSS 3.1 7.5 HIGHCheck source for fixed versionsCISA KEV

cve-program · CVE-2023-4346

Published

KNX devices that use KNX Connection Authorization and support Option 1 are, depending on the implementation, vulnerable to being locked and users being unable to reset them to gain access to the device. The BCU key feature on the devices can be used to create a password for the device, but this password can often not be reset without entering the current password. If the device is configured to interface with a network, an attacker with access to that network could interface with the KNX installation, purge all devices without additional security options enabled, and set a BCU key, locking the device. Even if a device is not connected to a network, an attacker with physical access to the device could also exploit this vulnerability in the same way.

Read the publisher's advisory

Affected versions, risk and source history

Exploitation and risk

Source status

CISA KEV lists vulnerabilities known to be exploited. FIRST EPSS estimates the likelihood of exploitation in the next 30 days. An unavailable score does not mean zero risk.

Which CVEs have scores here?

This view includes predictions for CVE identifiers explicitly listed in public NuGet advisories. Microsoft release pages have their own prediction coverage. Check source status for the scope and latest checks.

CVE-2023-4346

This is a saved version of the risk data. The advisory details have their own history. Latest risk data.

Listed in CISA KEV · added 15 Jul 2026 · KNX Association · KNX Protocol Connection Authorization Option 1

KNX Association KNX Protocol Connection Authorization Option 1 contains an overly restrictive account lockout mechanism vulnerability that could allow an attacker to purge all devices without additional security options enabled and set a BCU key to lock the device.

CISA source · CISA-cited reference

No EPSS score is available here for this CVE.

Saved 23 Oct 2026 16:01:26 UTC · View this risk record (JSON)

Advisory history

1 saved versions

See how the publisher's advisory changed over time. Each link opens the version saved at that time. The publisher's update date can differ from the date shown here.

How advisory history works

Each link identifies one complete publisher record. History can include advisories that previously shared an identifier; an identifier removed by a publisher no longer establishes a current relationship. A historical link shows only that record and earlier saved versions. Failed checks and unchanged reads do not create new versions.

23 Oct 2026 15:48:27 UTC

KNX devices that use KNX Connection Authorization and support Option 1 are, depending on the implementation, vulnerable to being locked and users being unable to reset them to gain access to the device. The BCU key feature on the devices ca…

cve-program · CVE-2023-4346 · Published

ChangeIntel

An IT change radar: releases, security, known issues, retirements, documentation changes, and service status from public sources. Every item links to supporting evidence; dates and statuses can change after they are read.

Sources read 24 Nov 17:05 UTC · 273 of 275 readable · 269 fully read · documentation 469/469 current