OpenBao exists to provide a software solution to manage, store, and distribute sensitive data including secrets, certificates, and keys. In versions 2.3.1 and below, OpenBao's Login Multi-Factor Authentication (MFA) system allows enforcing MFA using Time-based One Time Password (TOTP). Due to normalization applied by the underlying TOTP library, codes were accepted which could contain whitespace; this whitespace could bypass internal rate limiting of the MFA method and allow reuse of existing MFA codes. This issue was fixed in version 2.3.2. To work around this, use of rate-limiting quotas can limit an attacker's ability to exploit this: https://openbao.org/api-docs/system/rate-limit-quotas/.
See how the publisher's advisory changed over time. Each link opens the version saved at that time. The publisher's update date can differ from the date shown here.
How advisory history works
Each link identifies one complete publisher record. History can include advisories that previously shared an identifier; an identifier removed by a publisher no longer establishes a current relationship. A historical link shows only that record and earlier saved versions. Failed checks and unchanged reads do not create new versions.
OpenBao exists to provide a software solution to manage, store, and distribute sensitive data including secrets, certificates, and keys. In versions 2.3.1 and below, OpenBao's Login Multi-Factor Authentication (MFA) system allows enforcing …