Rockwell Automation FactoryTalk® Activation Manager - Privilege Escalation
Historical advisory recorded 23 Oct 2026 15:48:27 UTC. Read the latest advisory.
cve-program · CVE-2026-16675
PublishedA privilege escalation security issue exists within FactoryTalk® Activation Manager. The security issue stems from custom actions in the installer that spawn visible console windows running with SYSTEM privileges during installation or repair operations. An authenticated attacker with Windows credentials could hijack these console windows to obtain a SYSTEM-level command prompt, allowing full access to all files, processes, and system resources.
Read the publisher's advisoryAffected versions, risk and source history
cve-program · CVE-2026-16675
PublishedRockwell Automation FactoryTalk® Activation Manager - Privilege Escalation
A privilege escalation security issue exists within FactoryTalk® Activation Manager. The security issue stems from custom actions in the installer that spawn visible console windows running with SYSTEM privileges during installation or repair operations. An authenticated attacker with Windows credentials could hijack these console windows to obtain a SYSTEM-level command prompt, allowing full access to all files, processes, and system resources.
- Source published
- 1 Sep 2026 13:18:58 UTC
- Source modified
- 1 Sep 2026 15:42:20 UTC
- Saved here
- 23 Oct 2026 15:48:27 UTC
- Source terms
- CVE Program Terms of Use
Original source record · Cite this exact observation · Complete original publisher JSON
Source: cve-program · CVE Program Terms of Use. The publisher's wording is preserved. ChangeIntel groups the information and labels changes. The JSON record includes additional source fields.
CVSS 4.0 · 8.5 CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N