Electron: USB device selection not validated against filtered device list
Historical advisory recorded 23 Oct 2026 15:48:27 UTC. Read the latest advisory.
cve-program · CVE-2026-34766
PublishedElectron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. Prior to versions 38.8.6, 39.8.0, 40.7.0, and 41.0.0-beta.8, the select-usb-device event callback did not validate the chosen device ID against the filtered list that was presented to the handler. An app whose handler could be influenced to select a device ID outside the filtered set would grant access to a device that did not match the renderer's requested filters or was listed in exclusionFilters. The WebUSB security blocklist remained enforced regardless, so security-sensitive devices on the blocklist were not affected. The practical impact is limited to apps with unusual device-selection logic. This issue has been patched in versions 38.8.6, 39.8.0, 40.7.0, and 41.0.0-beta.8.
Read the publisher's advisoryAffected versions, risk and source history
Related advisories and sources
Publishers link these advisories through the identifiers shown below. A shared identifier or date alone does not tell you whether your software is affected or whether the advisories describe the same cause.
CVE-2026-34766 · CVE overview and exploitation status
cve-program · CVE-2026-34766
This historical advisory does not include today's related changes. Open the latest advisory to find current connections.