MZ Automation lib60870 Out-of-bounds Read
Historical advisory recorded 23 Oct 2026 15:48:27 UTC. Read the latest advisory.
cve-program · CVE-2026-61893
PublishedA crafted IEC 60870-5-104 I-frame with TypeID 104 (C_TS_NA_1) and an inflated object count causes TestCommand_getFromBuffer to read one byte past the end of the heap-allocated message buffer.
Read the publisher's advisoryAffected versions, risk and source history
cve-program · CVE-2026-61893
PublishedMZ Automation lib60870 Out-of-bounds Read
A crafted IEC 60870-5-104 I-frame with TypeID 104 (C_TS_NA_1) and an inflated object count causes TestCommand_getFromBuffer to read one byte past the end of the heap-allocated message buffer.
- Source published
- 30 Jul 2026 22:58:32 UTC
- Source modified
- 31 Jul 2026 16:00:07 UTC
- Saved here
- 23 Oct 2026 15:48:27 UTC
- Source terms
- CVE Program Terms of Use
Original source record · Cite this exact observation · Complete original publisher JSON
Source: cve-program · CVE Program Terms of Use. The publisher's wording is preserved. ChangeIntel groups the information and labels changes. The JSON record includes additional source fields.
CVSS 3.1 · 6.5 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L
CVSS 4.0 · 6.9 CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:L/SC:N/SI:N/SA:N