net: dsa: mxl862xx: fix use-after-free of DSA ports in crc_err_work
Historical advisory recorded 23 Oct 2026 15:48:27 UTC. Read the latest advisory.
cve-program · CVE-2026-72411
PublishedIn the Linux kernel, the following vulnerability has been resolved: net: dsa: mxl862xx: fix use-after-free of DSA ports in crc_err_work Upon an MDIO CRC error mxl862xx_crc_err_work_fn() walks the DSA ports and closes the CPU port conduits: dsa_switch_for_each_cpu_port(dp, priv->ds) dev_close(dp->conduit); mxl862xx_remove() unregisters the switch before cancelling this work: set_bit(MXL862XX_FLAG_WORK_STOPPED, &priv->flags); cancel_delayed_work_sync(&priv->stats_work); dsa_unregister_switch(ds); mxl862xx_host_shutdown(priv); dsa_unregister_switch() frees the dsa_port objects. If a CRC error schedules the work during teardown it can run after the ports have been freed and dereference freed memory. Guard the port walk with MXL862XX_FLAG_WORK_STOPPED, which is already set before dsa_unregister_switch(). DSA tears the ports down under rtnl_lock(), so checking the flag under rtnl_lock() means the work either runs before teardown and sees valid ports, or runs afterwards, observes the flag and skips the walk. This mirrors the host_flood_work handler, which skips torn-down ports under rtnl_lock().
Read the publisher's advisoryAffected versions, risk and source history
cve-program · CVE-2026-72411
Publishednet: dsa: mxl862xx: fix use-after-free of DSA ports in crc_err_work
In the Linux kernel, the following vulnerability has been resolved: net: dsa: mxl862xx: fix use-after-free of DSA ports in crc_err_work Upon an MDIO CRC error mxl862xx_crc_err_work_fn() walks the DSA ports and closes the CPU port conduits: dsa_switch_for_each_cpu_port(dp, priv->ds) dev_close(dp->conduit); mxl862xx_remove() unregisters the switch before cancelling this work: set_bit(MXL862XX_FLAG_WORK_STOPPED, &priv->flags); cancel_delayed_work_sync(&priv->stats_work); dsa_unregister_switch(ds); mxl862xx_host_shutdown(priv); dsa_unregister_switch() frees the dsa_port objects. If a CRC error schedules the work during teardown it can run after the ports have been freed and dereference freed memory. Guard the port walk with MXL862XX_FLAG_WORK_STOPPED, which is already set before dsa_unregister_switch(). DSA tears the ports down under rtnl_lock(), so checking the flag under rtnl_lock() means the work either runs before teardown and sees valid ports, or runs afterwards, observes the flag and skips the walk. This mirrors the host_flood_work handler, which skips torn-down ports under rtnl_lock().
- Source published
- 15 Aug 2026 05:56:33 UTC
- Source modified
- 17 Aug 2026 05:43:51 UTC
- Saved here
- 23 Oct 2026 15:48:27 UTC
- Source terms
- CVE Program Terms of Use
Original source record · Cite this exact observation · Complete original publisher JSON
Source: cve-program · CVE Program Terms of Use. The publisher's wording is preserved. ChangeIntel groups the information and labels changes. The JSON record includes additional source fields.
CVSS 3.1 · 7.8 CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H