Security Advisory catalog CVE-2026-80144
Historical advisory recorded 23 Oct 2026 15:48:27 UTC. Read the latest advisory .
cve-program · CVE-2026-80144 Published
Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers to execute arbitrary shell commands as root by exploiting an undocumented mfc eeprom write command that passes unsanitized user input to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices.
Read the publisher's advisory Affected versions, risk and source history
Overview Affected History Connections
cve-program · CVE-2026-80144 Published SLC8000 Vendor product
Publisher's version information Shown as published. These rules are not interpreted as NuGet package version ranges.
{
"defaultStatus": "unaffected",
"vendor": "LANTRONIX",
"product": "SLC8000",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThan": "9.7.0.2"
}
]
} EMG8500 Vendor product
Publisher's version information Shown as published. These rules are not interpreted as NuGet package version ranges.
{
"defaultStatus": "unaffected",
"vendor": "LANTRONIX",
"product": "EMG8500",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThan": "9.7.0.1"
}
]
} EMG7500 Vendor product
Publisher's version information Shown as published. These rules are not interpreted as NuGet package version ranges.
{
"defaultStatus": "unaffected",
"vendor": "LANTRONIX",
"product": "EMG7500",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThan": "9.7.0.1"
}
]
} SLB882 Vendor product
Publisher's version information Shown as published. These rules are not interpreted as NuGet package version ranges.
{
"defaultStatus": "unknown",
"vendor": "LANTRONIX",
"product": "SLB882",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
} SLCx-03 Vendor product
Publisher's version information Shown as published. These rules are not interpreted as NuGet package version ranges.
{
"defaultStatus": "unknown",
"vendor": "LANTRONIX",
"product": "SLCx-03",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
} SLCx-02 Vendor product
Publisher's version information Shown as published. These rules are not interpreted as NuGet package version ranges.
{
"defaultStatus": "unaffected",
"vendor": "LANTRONIX",
"product": "SLCx-02",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
} SLC9000 Vendor product
Publisher's version information Shown as published. These rules are not interpreted as NuGet package version ranges.
{
"defaultStatus": "unaffected",
"vendor": "LANTRONIX",
"product": "SLC9000",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThan": "9.7.0.2"
}
]