iommu/amd: Fix ineffective error check in nested domain allocation
Exact source revision recorded 23 Oct 2026 15:48:27 UTC. It does not establish the source's current position. Latest evidence.
cve-program · CVE-2026-98002
PublishedIn the Linux kernel, the following vulnerability has been resolved: iommu/amd: Fix ineffective error check in nested domain allocation amd_iommu_pdom_id_alloc() returns an int: a domain ID on success, or the negative errno from ida_alloc_range() when the ID space is exhausted or memory is short. amd_iommu_alloc_domain_nested() stores that return value in gdom_info->hdom_id, which is a u32, and only then tests it: gdom_info->hdom_id = amd_iommu_pdom_id_alloc(); if (gdom_info->hdom_id <= 0) { The assignment discards the sign, so -ENOSPC becomes 0xffffffe4 and the test never fires. The nested domain is then set up with a host domain ID that was never allocated, instead of the allocation failing with -ENOSPC. Keep the value in an int, test it there, and store it only once it is known to be valid, which is what the other amd_iommu_pdom_id_alloc() callers already do.
- Source published
- 25 Sep 2026 10:23:29 UTC
- Source modified
- 19 Oct 2026 09:12:07 UTC
- Observed here
- 23 Oct 2026 15:48:27 UTC
- Source terms
- CVE Program Terms of Use
Original source record · Cite this exact observation · Complete original publisher JSON
This view projects the publisher's source fields for reading; the original JSON retains additional fields and CVE enrichment containers. Attribution: cve-program · CVE Program Terms of Use. Source text is retained; field grouping and change labels are provided by ChangeIntel.
CVSS 3.1 · 7.8 CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H