Public mode

No access to your tenant or devices. Every item links to its source. What this means

Sources need attention Customize Public modeDiscuss ChangeIntel on Discord

FUXA: SQL injection in TDengine DAQ connector via backslash bypass of escapeTdString

Exploitation and risk

Source status

CISA KEV lists vulnerabilities known to be exploited. FIRST EPSS estimates the likelihood of exploitation in the next 30 days. An unavailable score does not mean zero risk.

Which CVEs have scores here?

This view includes predictions for CVE identifiers explicitly listed in public NuGet advisories. Microsoft release pages have their own prediction coverage. Check source status for the scope and latest checks.

No exploitation or prediction data is available here for these CVEs. This does not mean they are safe or unlikely to be exploited.

cve-program · CVE-2026-47720

Published

FUXA is a web-based Process Visualization (SCADA/HMI/Dashboard) software. Prior to 1.3.2, the TDengine DAQ storage connector's escapeTdString function in server/runtime/storage/tdengine/index.js doubles single quotes but does not escape backslashes. A remote unauthenticated attacker can submit a crafted sids tag identifier through GET /api/daq or the Socket.IO DAQ_QUERY event so TDengine interprets the backslash and quote sequence as SQL syntax. The injected query can return every row from fuxa.meters, exposing historical PLC tag values, device identifiers, and device names even when FUXA authentication is enabled. This issue is fixed in version 1.3.2.

Source published
18 Aug 2026 19:58:26 UTC
Source modified
19 Aug 2026 13:10:57 UTC
Saved here
23 Oct 2026 15:48:27 UTC
Source terms
CVE Program Terms of Use

Original source record · Cite this exact observation · Complete original publisher JSON

Source: cve-program · CVE Program Terms of Use. The publisher's wording is preserved. ChangeIntel groups the information and labels changes. The JSON record includes additional source fields.

CVSS 3.1 · 5.3 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N

euvd · EUVD-2026-61207

Published

FUXA is a web-based Process Visualization (SCADA/HMI/Dashboard) software. Prior to 1.3.2, the TDengine DAQ storage connector's escapeTdString function in server/runtime/storage/tdengine/index.js doubles single quotes but does not escape backslashes. A remote unauthenticated attacker can submit a crafted sids tag identifier through GET /api/daq or the Socket.IO DAQ_QUERY event so TDengine interprets the backslash and quote sequence as SQL syntax. The injected query can return every row from fuxa.meters, exposing historical PLC tag values, device identifiers, and device names even when FUXA authentication is enabled. This issue is fixed in version 1.3.2.

Additional publisher context

EUVD source date text has no stated timezone and is retained without inventing a UTC instant. Related bulletin membership is not an alias, common cause or applicability claim. A missing vector with a zero score is treated as unrated. Complete vendor/product and underlying source evidence remains in the original JSON.

Original publisher date fields

datePublished: Aug 18, 2026, 7:58:26 PM

dateUpdated: Aug 19, 2026, 1:10:57 PM

Source published
Aug 18, 2026, 7:58:26 PM (timezone not stated)
Source modified
Aug 19, 2026, 1:10:57 PM (timezone not stated)
Saved here
19 Nov 2026 16:07:08 UTC
Source terms
ENISA EUVD · source terms and attribution apply

Original source record · Cite this exact observation · Complete original publisher JSON

Source: euvd · ENISA EUVD · source terms and attribution apply. The publisher's wording is preserved. ChangeIntel groups the information and labels changes. The JSON record includes additional source fields.

EUVD CVSS 3.1 · 5.3 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N

nvd · CVE-2026-47720

Published

FUXA is a web-based Process Visualization (SCADA/HMI/Dashboard) software. Prior to 1.3.2, the TDengine DAQ storage connector's escapeTdString function in server/runtime/storage/tdengine/index.js doubles single quotes but does not escape backslashes. A remote unauthenticated attacker can submit a crafted sids tag identifier through GET /api/daq or the Socket.IO DAQ_QUERY event so TDengine interprets the backslash and quote sequence as SQL syntax. The injected query can return every row from fuxa.meters, exposing historical PLC tag values, device identifiers, and device names even when FUXA authentication is enabled. This issue is fixed in version 1.3.2.

Additional publisher context

NVD analysis and CPE criteria are source context, not proof that a package or your environment is affected. Complete affected data, logical configurations and SSVC are retained in the original JSON.

Source analysis status: Deferred

Weakness classifications: CWE-89

Original publisher date fields

published: 2026-08-18T20:17:15.250

lastModified: 2026-11-09T20:10:00.200

Source published
18 Aug 2026 20:17:15 UTC
Source modified
9 Nov 2026 20:10:00 UTC
Saved here
10 Nov 2026 16:25:39 UTC
Source terms
NIST NVD usage terms; underlying source attribution retained

Original source record · Cite this exact observation · Complete original publisher JSON

Source: nvd · NIST NVD usage terms; underlying source attribution retained. The publisher's wording is preserved. ChangeIntel groups the information and labels changes. The JSON record includes additional source fields.

CVSS 3.1 · [email protected] · Secondary · 5.3 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N

osv · GHSA-h9fj-c2qr-76g2

Published

## Summary The TDengine DAQ storage connector's `escapeTdString` at `server/runtime/storage/tdengine/index.js:10` doubles single quotes but does not escape backslashes. TDengine's SQL parser treats `\'` as a literal single quote inside a string, so a tag id of the form `x\' OR 1=1--` escapes the first single quote, lets the doubled quote close the string, and appends an injected clause that runs on the TDengine server. An attacker (Alice) sends the crafted `sids` value through `GET /api/daq` or the Socket.IO `DAQ_QUERY` event and reads every row in `fuxa.meters`, which holds the historical tag values of every PLC the FUXA instance records. ## Details The TDengine DAQ storage connector did not correctly sanitize user-controlled values before including them in SQL queries. A specially crafted tag identifier could bypass the intended escaping logic and alter the query executed against the TDengine database. This could allow unauthorized access to historical DAQ data stored in TDengine, including recorded tag values and related metadata. The issue has been fixed in version 1.3.2 by improving input escaping in the TDengine connector. ## Impact An attacker with network access to a FUXA instance configured with TDengine as the DAQ backend reads the entire historical tag-value archive: every PLC tag the instance has recorded, plus the associated device ids and device names. Turning on authentication does not close the gap: the Socket.IO `DAQ_QUERY` handler has no authorization check, and `/api/daq` accepts guest-level requests. No login is needed in the default configuration. **CVSS 3.1**: `AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N` (Medium, 5.3). CWE-89. --- A fix is available at https://github.com/frangoteam/FUXA/releases/tag/v1.3.2. --- *Found by [aisafe.io](https://aisafe.io)*

Source published
8 Jun 2026 23:06:43 UTC
Source modified
8 Jun 2026 23:26:36 UTC
Saved here
24 Oct 2026 13:17:17 UTC
Source terms
GitHub Advisory Database · CC-BY-4.0

Original source record · Cite this exact observation · Complete original publisher JSON

Source: osv · GitHub Advisory Database · CC-BY-4.0. The publisher's wording is preserved. ChangeIntel groups the information and labels changes. The JSON record includes additional source fields.

CVSS_V3 · CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N

Publisher rating · MODERATE

ChangeIntel

An IT change radar: releases, security, known issues, retirements, documentation changes, and service status from public sources. Every item links to supporting evidence; dates and statuses can change after they are read.

Sources read 21 Nov 10:21 UTC · 274 of 275 readable · 270 fully read · documentation 469/469 current