Public mode

No access to your tenant or devices. Every item links to its source. What this means

Sources need attention Customize Public modeDiscuss ChangeIntel on Discord

Diesel has possible use after free when deserializing a SQLite database via `SqliteConnection::deserialize_readonly_database`

Exploitation and risk

Source status

CISA KEV lists vulnerabilities known to be exploited. FIRST EPSS estimates the likelihood of exploitation in the next 30 days. An unavailable score does not mean zero risk.

Which CVEs have scores here?

This view includes predictions for CVE identifiers explicitly listed in public NuGet advisories. Microsoft release pages have their own prediction coverage. Check source status for the scope and latest checks.

No exploitation or prediction data is available here for these CVEs. This does not mean they are safe or unlikely to be exploited.

osv · GHSA-ggxf-9f6j-w742

Published

Diesel allows loading a SQLite database from a byte buffer, represented as `&[u8]`, at runtime via the `SqliteConnection::deserialize_readonly_database` function. In previous versions of Diesel, this buffer was passed directly to libsqlite3. Since libsqlite3 requires the buffer to remain alive for as long as the database connection is open and Diesel did not ensure this as part of its safe API, callers of `SqliteConnection::deserialize_readonly_database` could drop the buffer prematurely. This prematurely drop caused libsqlite3 to operate on freed memory. This vulnerability affects users of `SqliteConnection::deserialize_readonly_database` who drop the buffer passed to the function before they drop the database connection. ## Mitigation The preferred mitigation to the outlined problem is to update to Diesel version 2.3.10 or newer, which includes a fix for the problem. Alternatively users need to take to keep the buffer alive until the connection is dropped. ## Resolution Diesel now stores a copy of the buffer inside of the `SqliteConnection` object itself to keep it alive as long as the underlying libsqlite3 connection exists.

Source published
16 Jul 2026 19:25:25 UTC
Source modified
17 Jul 2026 08:56:39 UTC
Saved here
24 Oct 2026 13:19:54 UTC
Source terms
GitHub Advisory Database · CC-BY-4.0

Original source record · Cite this exact observation · Complete original publisher JSON

Source: osv · GitHub Advisory Database · CC-BY-4.0. The publisher's wording is preserved. ChangeIntel groups the information and labels changes. The JSON record includes additional source fields.

CVSS_V4 · CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N

Publisher rating · MODERATE

osv · RUSTSEC-2026-0172

Published

Diesel allows loading a SQLite database from a byte buffer, represented as `&[u8]`, at runtime via the `SqliteConnection::deserialize_readonly_database` function. In previous versions of Diesel, this buffer was passed directly to libsqlite3. Since libsqlite3 requires the buffer to remain alive for as long as the database connection is open and Diesel did not ensure this as part of its safe API, callers of `SqliteConnection::deserialize_readonly_database` could drop the buffer prematurely. This prematurely drop caused libsqlite3 to operate on freed memory. This vulnerability affects users of `SqliteConnection::deserialize_readonly_database` who drop the buffer passed to the function before they drop the database connection. ## Mitigation The preferred mitigation to the outlined problem is to update to Diesel version 2.3.10 or newer, which includes a fix for the problem. Alternatively users need to take to keep the buffer alive until the connection is dropped. ## Resolution Diesel now stores a copy of the buffer inside of the `SqliteConnection` object itself to keep it alive as long as the underlying libsqlite3 connection exists.

Source published
5 Jun 2026 12:00:00 UTC
Source modified
17 Jul 2026 08:45:04 UTC
Saved here
24 Oct 2026 13:19:54 UTC
Source terms
OSV · upstream source license applies

Original source record · Cite this exact observation · Complete original publisher JSON

Source: osv · OSV · upstream source license applies. The publisher's wording is preserved. ChangeIntel groups the information and labels changes. The JSON record includes additional source fields.

ChangeIntel

An IT change radar: releases, security, known issues, retirements, documentation changes, and service status from public sources. Every item links to supporting evidence; dates and statuses can change after they are read.

Sources read 24 Nov 15:03 UTC · 274 of 275 readable · 270 fully read · documentation 469/469 current