osv · GHSA-r4pf-3v7r-hh55
Published### Impact Windows-Only: The NSIS installer makes a system call to open cmd.exe via NSExec in the `.nsh` installer script. NSExec by default searches the current directory of where the installer is located before searching `PATH`. This means that if an attacker can place a malicious executable file named cmd.exe in the same folder as the installer, the installer will run the malicious file. ### Patches Fixed in https://github.com/electron-userland/electron-builder/pull/8059 ### Workarounds None, it executes at the installer-level before the app is present on the system, so there's no way to check if it exists in a current installer. ### References https://cwe.mitre.org/data/definitions/426.html https://cwe.mitre.org/data/definitions/427
- Source published
- 4 Mar 2024 20:42:45 UTC
- Source modified
- 10 Sep 2026 03:50:10 UTC
- Saved here
- 24 Oct 2026 13:17:17 UTC
- Source terms
- GitHub Advisory Database · CC-BY-4.0
Original source record · Cite this exact observation · Complete original publisher JSON
Source: osv · GitHub Advisory Database · CC-BY-4.0. The publisher's wording is preserved. ChangeIntel groups the information and labels changes. The JSON record includes additional source fields.
CVSS_V3 · CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
Publisher rating · HIGH