n/a · cross-site scripting
cve-program · CVE-2023-46344
PublishedA vulnerability in Solar-Log Base 15 Firmware 6.0.1 Build 161, and possibly other Solar-Log Base products, allows an attacker to escalate their privileges by exploiting a stored cross-site scripting (XSS) vulnerability in the switch group function under /#ilang=DE&b=c_smartenergy_swgroups in the web portal. The vulnerability can be exploited to gain the rights of an installer or PM, which can then be used to gain administrative access to the web portal and execute further attacks. NOTE: The vendor states that this vulnerability has been fixed with 3.0.0-60 11.10.2013 for SL 200, 500, 1000 / not existing for SL 250, 300, 1200, 2000, SL 50 Gateway, SL Base.
Read the publisher's advisoryAffected versions, risk and source history
Exploitation and risk
Source statusCISA KEV lists vulnerabilities known to be exploited. FIRST EPSS estimates the likelihood of exploitation in the next 30 days. An unavailable score does not mean zero risk.
Which CVEs have scores here?
This view includes predictions for CVE identifiers explicitly listed in public NuGet advisories. Microsoft release pages have their own prediction coverage. Check source status for the scope and latest checks.
No exploitation or prediction data is available here for these CVEs. This does not mean they are safe or unlikely to be exploited.
cve-program · CVE-2023-46344
PublishedA vulnerability in Solar-Log Base 15 Firmware 6.0.1 Build 161, and possibly other Solar-Log Base products, allows an attacker to escalate their privileges by exploiting a stored cross-site scripting (XSS) vulnerability in the switch group f…
A vulnerability in Solar-Log Base 15 Firmware 6.0.1 Build 161, and possibly other Solar-Log Base products, allows an attacker to escalate their privileges by exploiting a stored cross-site scripting (XSS) vulnerability in the switch group function under /#ilang=DE&b=c_smartenergy_swgroups in the web portal. The vulnerability can be exploited to gain the rights of an installer or PM, which can then be used to gain administrative access to the web portal and execute further attacks. NOTE: The vendor states that this vulnerability has been fixed with 3.0.0-60 11.10.2013 for SL 200, 500, 1000 / not existing for SL 250, 300, 1200, 2000, SL 50 Gateway, SL Base.
- Source published
- 2 Feb 2024 00:00:00 UTC
- Source modified
- 9 Jul 2026 00:28:41 UTC
- Saved here
- 23 Oct 2026 15:48:27 UTC
- Source terms
- CVE Program Terms of Use
Original source record · Cite this exact observation · Complete original publisher JSON
Source: cve-program · CVE Program Terms of Use. The publisher's wording is preserved. ChangeIntel groups the information and labels changes. The JSON record includes additional source fields.