Public mode

No access to your tenant or devices. Every item links to its source. What this means

Sources need attention Customize Public modeDiscuss ChangeIntel on Discord

CC-Link IE TSN Remote I/O module NZ2GN2S1-32D · Vulnerability

CVSS 3.1 7.5 HIGHCheck source for fixed versionsKEV status unknown

cve-program · CVE-2025-3511

Published

Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module, CC-Link IE TSN Analog-Digital Converter module, CC-Link IE TSN Digital-Analog Converter module, CC-Link IE TSN FPGA module, CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY, MELSEC iQ-R Series CC-Link IE TSN Master/Local Module, MELSEC iQ-R Series Ethernet Interface Module, CC-Link IE TSN Master/Local Station Communication LSI CP610, MELSEC iQ-F Series FX5 CC-Link IE TSN Master/Local Module, MELSEC iQ-F Series FX5 Ethernet Module, MELSEC iQ-F Series FX5-ENET/IP Ethernet Module, and MELSEC iQ-R Series CPU module allows a remote unauthenticated attacker to cause a Denial of Service condition in the products by sending specially crafted UDP packets.

Read the publisher's advisory

Affected versions, risk and source history

Exploitation and risk

Source status

CISA KEV lists vulnerabilities known to be exploited. FIRST EPSS estimates the likelihood of exploitation in the next 30 days. An unavailable score does not mean zero risk.

Which CVEs have scores here?

This view includes predictions for CVE identifiers explicitly listed in public NuGet advisories. Microsoft release pages have their own prediction coverage. Check source status for the scope and latest checks.

No exploitation or prediction data is available here for these CVEs. This does not mean they are safe or unlikely to be exploited.

cve-program · CVE-2025-3511

Published

Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module, CC-Link IE TSN Analog-Digital Converter module, CC-Link IE TSN Digital-Analog Converter module, CC-Link IE…

Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module, CC-Link IE TSN Analog-Digital Converter module, CC-Link IE TSN Digital-Analog Converter module, CC-Link IE TSN FPGA module, CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY, MELSEC iQ-R Series CC-Link IE TSN Master/Local Module, MELSEC iQ-R Series Ethernet Interface Module, CC-Link IE TSN Master/Local Station Communication LSI CP610, MELSEC iQ-F Series FX5 CC-Link IE TSN Master/Local Module, MELSEC iQ-F Series FX5 Ethernet Module, MELSEC iQ-F Series FX5-ENET/IP Ethernet Module, and MELSEC iQ-R Series CPU module allows a remote unauthenticated attacker to cause a Denial of Service condition in the products by sending specially crafted UDP packets.

Source published
25 Apr 2025 05:14:43 UTC
Source modified
27 Aug 2026 05:32:29 UTC
Saved here
23 Oct 2026 15:48:27 UTC
Source terms
CVE Program Terms of Use

Original source record · Cite this exact observation · Complete original publisher JSON

Source: cve-program · CVE Program Terms of Use. The publisher's wording is preserved. ChangeIntel groups the information and labels changes. The JSON record includes additional source fields.

CVSS 3.1 · 7.5 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

ChangeIntel

An IT change radar: releases, security, known issues, retirements, documentation changes, and service status from public sources. Every item links to supporting evidence; dates and statuses can change after they are read.

Sources read 20 Nov 17:59 UTC · 274 of 275 readable · 270 fully read · documentation 469/469 current