Local privilege escalation via insecure folder permissions

CVSS 3.1 7.8 HIGHCheck source for fixed versionsKEV status unknown

cve-program · CVE-2026-114031

Published

Incorrect permission assignment allows local privilege escalation to SYSTEM on affected releases of the Illumio VEN for Windows. Code execution as NT AUTHORITY\LOCAL SERVICE on the Windows host is required to exploit this vulnerability. The flaw exists within the VEN installer, which grants LOCAL SERVICE full access to the VEN data and installation folders, whose configuration and state files are read and trusted by the SYSTEM-privileged illumio-ven-ctl component. An attacker can leverage this vulnerability to modify the VEN configuration so that illumio-ven-ctl executes an injected command in the context of the SYSTEM account.

Read the publisher's advisory

Affected versions, risk and source history

Exploitation and risk

Source status

CISA KEV lists vulnerabilities known to be exploited. FIRST EPSS estimates the likelihood of exploitation in the next 30 days. An unavailable score does not mean zero risk.

Which CVEs have scores here?

This view includes predictions for CVE identifiers explicitly listed in public NuGet advisories. Microsoft release pages have their own prediction coverage. Check source status for the scope and latest checks.

No exploitation or prediction data is available here for these CVEs. This does not mean they are safe or unlikely to be exploited.

cve-program · CVE-2026-114031

Published

Local privilege escalation via insecure folder permissions

Incorrect permission assignment allows local privilege escalation to SYSTEM on affected releases of the Illumio VEN for Windows. Code execution as NT AUTHORITY\LOCAL SERVICE on the Windows host is required to exploit this vulnerability. The flaw exists within the VEN installer, which grants LOCAL SERVICE full access to the VEN data and installation folders, whose configuration and state files are read and trusted by the SYSTEM-privileged illumio-ven-ctl component. An attacker can leverage this vulnerability to modify the VEN configuration so that illumio-ven-ctl executes an injected command in the context of the SYSTEM account.

Source published
9 Nov 2026 21:31:15 UTC
Source modified
12 Nov 2026 17:11:30 UTC
Saved here
12 Nov 2026 19:16:18 UTC
Source terms
CVE Program Terms of Use

Original source record · Cite this exact observation · Complete original publisher JSON

Source: cve-program · CVE Program Terms of Use. The publisher's wording is preserved. ChangeIntel groups the information and labels changes. The JSON record includes additional source fields.

CVSS 3.1 · 7.8 CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H