nerves_hub_web · Vulnerability
cve-program · CVE-2026-120295
PublishedIncorrect Authorization vulnerability in the devices page bulk move in nerves-hub nerves_hub_web allows an authenticated user with the manage role in one organization and only the view role in another to move devices into the second organization's product via the "Move device(s) to product" action. The target-product event in NervesHubWeb.Live.Devices.Index looks the product up with NervesHub.Products.get_by_id/2, which checks that the user is a member of the product's organization at any role, and move-devices-product then changes each selected device's organization and product. The device API's move requires manage in the target organization, and an earlier fix added the check on the organization the devices leave but not on the one they enter. A moved device keeps its key and certificate, joins the target organization's matching deployment groups, and is sent their firmware with a download URL, which the view role cannot otherwise obtain. The user cannot change or control devices that already belong to the other organization. This issue affects nerves_hub: from 1.0.0 before 2.5.3.
Read the publisher's advisoryAffected versions, risk and source history
Related advisories and sources
Publishers link these advisories through the identifiers shown below. A shared identifier or date alone does not tell you whether your software is affected or whether the advisories describe the same cause.
CVE-2026-120295 · CVE overview and exploitation status
cve-program · CVE-2026-120295
- https://github.com/nerves-hub/nerves_hub_web/security/advisories/GHSA-2j7r-q3vm-8j34
- https://cna.erlef.org/cves/CVE-2026-120295.html
- https://osv.dev/vulnerability/EEF-CVE-2026-120295
- https://github.com/nerves-hub/nerves_hub_web/commit/adaeefdb7a835525482588f43332ef988cc448c7
- https://github.com/nerves-hub/nerves_hub_web/commit/79743ef08f7f801617b653fd09f37c01ed9b4be0
- https://github.com/nerves-hub/nerves_hub_web/commit/1bc8be875ab6b1eb904e5ff60c8a1421c5c700fa
Related changes
Linked by CVE identifier- Incorrect authorization in the devices page bulk move allows view-role members to move devices into another organization and receive its firmware · Affected-version evidence changed · 11 Nov 2026
- Incorrect authorization in the devices page bulk move allows view-role members to move devices into another organization and receive its firmware · Affected-version evidence changed · 11 Nov 2026
- Incorrect authorization in the devices page bulk move allows view-role members to move devices into another organization and receive its firmware · Newly collected advisory · 10 Nov 2026