Public mode

No access to your tenant or devices. Every item links to its source. What this means

Sources need attention Customize Public modeDiscuss ChangeIntel on Discord

QNX Software Development Platform · Vulnerability

CVSS 3.1 6.4 MEDIUMCheck source for fixed versionsKEV status unknown

cve-program · CVE-2026-4018

Published

TOCTOU Race Condition in specific trace commands of the TraceEvent() system call could allow an attacker with local access and with the PROCMGR_AID_TRACE ability, to cause information disclosure, data tampering or a crash of the QNX Neutrino kernel.

Read the publisher's advisory

Affected versions, risk and source history

cve-program · CVE-2026-4018

Published

QNX Software Development Platform

Vendor product

Publisher's version information

Shown as published. These rules are not interpreted as NuGet package version ranges.

{
                    "vendor": "BlackBerry Ltd",
                    "product": "QNX Software Development Platform",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "7.1"
                        },
                        {
                            "status": "affected",
                            "version": "cpe:2.3:a:blackberry:qnx_software_development_platform:7.1:*:*:*:*:*:*:*",
                            "versionType": "cpe"
                        },
                        {
                            "status": "affected",
                            "version": "7.0"
                        },
                        {
                            "status": "affected",
                            "version": "cpe:2.3:a:blackberry:qnx_software_development_platform:7.0:*:*:*:*:*:*:*",
                            "versionType": "cpe"
                        }
                    ],
                    "defaultStatus": "unaffected"
                }

QNX OS for Safety

Vendor product

Publisher's version information

Shown as published. These rules are not interpreted as NuGet package version ranges.

{
                    "vendor": "BlackBerry Ltd",
                    "product": "QNX OS for Safety",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "2.2.8 and earlier"
                        },
                        {
                            "status": "affected",
                            "version": "cpe:2.3:o:blackberry:qnx_os_for_safety:2.2:8:*:*:*:*:*:*",
                            "versionType": "cpe"
                        },
                        {
                            "status": "affected",
                            "version": "2.1.5 and earlier"
                        },
                        {
                            "status": "affected",
                            "version": "cpe:2.3:o:blackberry:qnx_os_for_safety:2.1:5:*:*:*:*:*:*",
                            "versionType": "cpe"
                        },
                        {
                            "status": "affected",
                            "version": "2.0.3 and earlier"
                        },
                        {
                            "status": "affected",
                            "version": "cpe:2.3:o:blackberry:qnx_os_for_safety:2.0:3:*:*:*:*:*:*",
                            "versionType": "cpe"
                        }
                    ],
                    "defaultStatus": "unaffected"
                }

QNX OS for Medical

Vendor product

Publisher's version information

Shown as published. These rules are not interpreted as NuGet package version ranges.

{
                    "vendor": "BlackBerry Ltd.",
                    "product": "QNX OS for Medical",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "2.0.2 and earlier"
                        },
                        {
                            "status": "affected",
                            "version": "cpe:2.3:o:blackberry:qnx_os_for_medical:2.0:2:*:*:*:*:*:*",
                            "versionType": "cpe"
                        }
                    ],
                    "defaultStatus": "unaffected"
                }

Original source record · Cite this exact observation · Complete original publisher JSON

ChangeIntel

An IT change radar: releases, security, known issues, retirements, documentation changes, and service status from public sources. Every item links to supporting evidence; dates and statuses can change after they are read.

Sources read 24 Nov 17:05 UTC · 273 of 275 readable · 269 fully read · documentation 469/469 current