net: mctp i3c: clean up notifier and buses if driver register fails
cve-program · CVE-2026-68314
PublishedIn the Linux kernel, the following vulnerability has been resolved: net: mctp i3c: clean up notifier and buses if driver register fails mctp_i3c_mod_init() registers the I3C bus notifier and then walks the existing buses with i3c_for_each_bus_locked(mctp_i3c_bus_add_new, NULL) before registering the I3C device driver. If i3c_driver_register() fails, the function returns the error directly, leaving the notifier registered and every mctp_i3c_bus object created for the existing buses allocated. The notifier is left pointing into the module that failed to load and the bus list is leaked. Mirror the module exit path on this failure: unregister the notifier and tear down the buses that were added before returning the error. This issue was identified during our ongoing static-analysis research while reviewing kernel code.
Read the publisher's advisoryAffected versions, risk and source history
Exploitation and risk
Source statusCISA KEV lists vulnerabilities known to be exploited. FIRST EPSS estimates the likelihood of exploitation in the next 30 days. An unavailable score does not mean zero risk.
Which CVEs have scores here?
This view includes predictions for CVE identifiers explicitly listed in public NuGet advisories. Microsoft release pages have their own prediction coverage. Check source status for the scope and latest checks.
No exploitation or prediction data is available here for these CVEs. This does not mean they are safe or unlikely to be exploited.
cve-program · CVE-2026-68314
Publishednet: mctp i3c: clean up notifier and buses if driver register fails
In the Linux kernel, the following vulnerability has been resolved: net: mctp i3c: clean up notifier and buses if driver register fails mctp_i3c_mod_init() registers the I3C bus notifier and then walks the existing buses with i3c_for_each_bus_locked(mctp_i3c_bus_add_new, NULL) before registering the I3C device driver. If i3c_driver_register() fails, the function returns the error directly, leaving the notifier registered and every mctp_i3c_bus object created for the existing buses allocated. The notifier is left pointing into the module that failed to load and the bus list is leaked. Mirror the module exit path on this failure: unregister the notifier and tear down the buses that were added before returning the error. This issue was identified during our ongoing static-analysis research while reviewing kernel code.
- Source published
- 10 Aug 2026 12:02:49 UTC
- Source modified
- 17 Aug 2026 05:03:10 UTC
- Saved here
- 23 Oct 2026 15:48:27 UTC
- Source terms
- CVE Program Terms of Use
Original source record · Cite this exact observation · Complete original publisher JSON
Source: cve-program · CVE Program Terms of Use. The publisher's wording is preserved. ChangeIntel groups the information and labels changes. The JSON record includes additional source fields.