A stack-based buffer overflow vulnerability exists in the diagnostic execution utility of Brocade Fabric OS versions before 10.0.1. When processing command arguments for diagnostic operations, the utility tokenizes user-supplied input into …
Exact source revision recorded 23 Oct 2026 15:48:27 UTC. It does not establish the source's current position. Latest evidence.
cve-program · CVE-2026-87668
PublishedA stack-based buffer overflow vulnerability exists in the diagnostic execution utility of Brocade Fabric OS versions before 10.0.1. When processing command arguments for diagnostic operations, the utility tokenizes user-supplied input into an internal argument array without enforcing boundary checks on the maximum array capacity. An authenticated user with administrative access can exploit this vulnerability by supplying a crafted diagnostic command string containing an excessive number of tokenized arguments. This leads to a memory overwrite resulting in a denial of service (process crash).
- Source published
- 8 Oct 2026 03:00:54 UTC
- Source modified
- 8 Oct 2026 13:46:29 UTC
- Observed here
- 23 Oct 2026 15:48:27 UTC
- Source terms
- CVE Program Terms of Use
Original source record · Cite this exact observation · Complete original publisher JSON
This view projects the publisher's source fields for reading; the original JSON retains additional fields and CVE enrichment containers. Attribution: cve-program · CVE Program Terms of Use. Source text is retained; field grouping and change labels are provided by ChangeIntel.
CVSS 4.0 · 6.9 CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:N